Customization: | Available |
---|---|
Type: | Server Cabinet |
Usage: | Video Surveillance Systems, Network Integration System, Remote Monitoring System, Closed-Circuit Monitoring System, Electronic Monitoring System, Wireless Monitoring System |
Still deciding? Get samples of US$ 7999/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Specification | *Rack-mounted 6kVA UPS customized ; *9Ah Battery pack customized, *Total backup time is 10-15 min; *Rack-mounted distribution module customized (Including C-level lightning protection, power monitoring) *PDU customized; *4.2KW Rack-mounted precision air conditioning customized (including outdoor unit) *AU Monitoring host and monitoring software |
Difference | Gcabling Micro Data Center | Traditional Small Data Center |
Computer Room | No need,fully enclosed with low noise,can be installed directly in the corner ofoffice Single cabinet ocCupies an area of 0.7-1.0m |
Need,oCCupying an area of about 10-20m |
Decoration | No need | Need |
Operating Cost | Fully enclosed microenvironment,low energy consumption,with a PUE level around 1.5 |
Air conditioning cools the entire room,resulting in high electricity costs,with an overall energy efficiency level between 2.0 and 3.0 |
Management and Maintenance |
One-stop service,with IT personnel available on a part-time basis |
Multi vendor procurement,unclear responsibility interface,requiring maintenance and management by multiple professionals |
Installation | Overall design,plug and play | UPS,Airconditioners and cabinets are independently purchased and installed |
Construction Period |
1-2 days | 3-4 weeks |
Aesthetics | Appearance of the devices is coordinated and unified |
Poor consistency in appearance between devices |
Cleanliness | Fully enclosed environment,cleanliness comparable to cloud computing rooms |
Dependent on environmental conditions,long- term operation can easily accumulate dust, leading to device restart and downtime |
Noise | Noise level of 55dB (A),with minimal impact on the environment |
Noise level is 65-70dB (A),requires sound insulation treatment |
UPS | Placed inside a sealed cabinet,with precision air conditioning to ensure operation |
Independent UPS+battery cabinet,dependent on room temperature and cleanliness |
PDU | Equipped with SPD,well-known brand switches,and intelligent monitoring of power status |
Wall mounted installation,no guarantee of air switch brand,no monitoring,no SPD |
Air Conditioner | Specialized precision air conditioning,7×24 hour operation |
Civil air conditioning does not match the needsof server operation,resulting in a high failure rate |
Monitoring | Complete monitoring(temperature,humidity, smoke,water leakage,video,UPS,air conditioning,electricity,energy consumption, email and SMS alerts),constantly monitoring the operating status |
No monitoring or simple monitoring |